Print

Devita D


€ 5880,00
Description

The DeVita-D Hardware-Software Complex   ( Download Manual Here )
The hardware-software complex DeVita D is used for:

Measurement, by the R. Voll method, the electrical parameters of biologically active points (BAP).
Testing the effect of drugs on the human body, measuring by the method of vegetative reflex test (VRT).
Re-recording the properties of drugs (homeopathic, organopreparations, nosodes, toxins, etc.) on various carriers (water, alcohol, homeopathic

The DeVita-D it’s a 2-in-1 Hardware-Software Complex
DEVITA DDD

Measuring Unit
The action of the unit is based on the results of one of the most common electro acupuncture techniques - the R. Voll method, which uses measurements of electrical resistance of the skin for testing.
The method makes it possible to detect energy imbalances in the body, allowing you to monitor and detect possible abnormalities at an early stage.

Selector Unit
The action of the unit is based on the effect of recording the properties of drugs on an electronic carrier. Due to this, a structure is formed, which is further used as an “electronic container”, which in turn allows its application in the work according to H. Schimmel’s method.
The method is based on the fact that the source of information is a single “reproducible” point on which “preparations-pointers” are tested.

Content
DeVita D” device..........................................................................1 pc.

Measuring probe..........................................................................1 pc.
Hand electrode (bronze cylinder).................................................1 pc
Cuvette stand (aluminum plate)…………………………………….1 pc.
Honeycomb plate (aluminum base)..........................………...…..1 pc.
Beaker with lid (Aluminum)………………………………...………..1 pc.
Cable set......................................................................................1 pc.
Power supply unit.........................................................................1 pc.
Bag for carrying and storing the device........................................1 pc.
Operating instructions/pasport......................................................1 pc.

fm

Specification
Measuring unit
Measuring method .....................................................R. Voll method, H. Schimmel method

Conductivity range, units .................................................................................from 0 to 100
Measurment accuracy, % .................................................................................................±1
Measurment voltage, V .............................................................................................1,25±1%
Measurment current, µΑ.............................................................................................12,5±1%
“Stretching” of the VRT scale, units....................................................................................80
Sound in diagnostic mode.......................................................................................multitonal
Amplification of the active recording information, times by ................................................30
Overall dimensions of the measuring probe, not more than, mm, D x L ................. 16 х 170
Weight of the measuring probe, not more than, kg ...........................................................0,1
Selector unit
Number of preparation in the list, units..........................................................................17200

Nuber of preparations for writing, units .........................................................................18200
Maximum number of preparations to be connected simultaneously, units..........................18
Power supply unit
Power adapter............................................................................................220V\50Hz, 5V\3A
DeVita D device
Keyboard type......................................................................................................touch sensor
Display type.........................................................................................................TFT 240x320
Connection to a computer...........................................................................................USB 2.0
Overall dimensions not more than, mm...............................................................240х185х104
Weight:
without accessories and peripherals not more than, kg.......................................................0,8
whole set, not more than, kg................................................................................................2,5

EAV Pro 6.0
The EAVPro6 program is intended for the users of the DeVita-D and/or for the DeVita Professional with a BS-8 adapter.
To use the Device, the Application supports the following operating modes:
- Client archive,
- Appointment schedules,
- VRT examination results,
- Preparations & recommendations history.

Minimum system requirements
-Processor 1GHz
-RAM 1GB
-USB input

Screenshot 2024 07 16 162100

DeAquaDevita Combi
Back to: Devices